IP67 fully sealed, audible & vibration feedback – how one glass keyboard serves both disinfection and cleanroom environments
In medical and industrial environments, a keyboard must be more than an input device – it must become part of the environment itself: resistant to disinfectants, nonparticulating, easy to clean, and reliable to operate. The Bastron B45-USB glass keyboard is designed precisely for this purpose. Featuring a glass surface, IP67 dust/water ingress protection, and standard audible and tactile vibration feedback, the B45-USB series branches into two distinct variants: the medical keyboard and the industrial keyboard. Their design differences are significant and applicationdriven.

1. The Foundation of a Glass Keyboard
The B45-USB series is first and foremost a glass keyboard. The smooth, nonporous glass surface repels contaminants and withstands frequent wiping and chemical exposure. Unlike traditional plastic membrane or silicone keyboards, glass does not wear, crack, or discolor after repeated cleaning. To overcome the poor blindoperation experience typical of glass touch keyboards, the B45-USB series integrates audible and vibration feedback, providing a clear click sound and tactile pulse with each key press – ensuring operators can work confidently without looking down.
2. Medical Keyboard: Built for Immersion Disinfection
The Bastron B45-USB medical keyboard is designed to endure repeated, aggressive disinfection. In operating rooms, ICUs, pharmaceutical cleanrooms, or food processing lines, the keyboard must withstand direct spraying or even immersion in disinfectant solutions.
· Grooveless design – The medical version features a fully sealed, seamless glass surface with no gaps or recesses, preventing disinfectant residue or bacterial buildup.
· Immersionready – The keyboard body can be independently submerged in disinfectant solution, or locked to prevent false triggering and then sprayed/wiped directly. The glass surface and feedback mechanisms are fully sealed, blocking liquid ingress.
· USB port with silicone cap – The interface is covered by a silicone cap, which seals the port during cleaning to prevent short circuits and protect against corrosive disinfectants.
Thus, the B45-USB medical keyboard is suitable not only for hospitals but also for food, pharmaceutical, and cosmetic manufacturing environments that require strict disinfection.
3. Industrial Keyboard: Built for Cleanrooms and Interference Immunity
The Bastron B45-USB industrial keyboard targets Class 100 and below cleanrooms as well as automated factory floors. Its focus shifts from chemical disinfection to particulate control and electrical stability.
· No silicone antislip pads – Eliminates particle generation or dust attraction in cleanroom settings.
· Direct USB cable exit – Fixed cabling removes the failure point and particle risk associated with detachable connectors.
· Antiinterference option available – For environments with VFDs, motors, and PLCs, the industrial keyboard comes in standard USB and antiinterference versions to ensure signal integrity.
· VESAmountable version – Allows the keyboard to be secured to a console, cabinet, or articulating arm, preventing slippage in vibrating environments.
This industrial keyboard also meets IP67 ratings – fully dusttight and resistant to temporary immersion – but is not designed for submersion disinfection.
4. Common Features: IP67 and Feedback
Regardless of variant, every B45-USB series keyboard shares these core attributes:
· IP67 dust/water protection – Completely dusttight and protected against immersion in 1 meter of water for 30 minutes.
· Glass surface – Scratchresistant, chemicalresistant, and easy to clean.
· Audible + vibration feedback – Enables accurate operation even with gloves or when the user cannot see the keyboard.
5. Selection Summary
Feature | B45-USB Medical Keyboard | B45-USB Industrial Keyboard |
Primary mission | Repeated disinfection, immersion tolerance | Particle control, EMI immunity |
Surface design | Grooveless sealed glass | Glass surface (no silicone pads) |
Disinfection method | Immersion, spraying, wiping | Wiping only (immersion not recommended) |
USB interface | Siliconecapped port | Direct USB cable exit |
Antiinterference | Not emphasized | Optional antiinterference version |
Mounting | Desktop, mobile use | Optional VESA mounting |
Typical environment | Hospitals, pharma, food | Cleanrooms, automated production lines |
When selecting a Bastron B45-USB glass keyboard, first ask whether your environment requires immersion disinfection – if yes, choose the medical keyboard. If you operate in a cleanroom or electrically noisy industrial site, choose the industrial keyboard. Born from the same platform, each variant is optimized for its own harsh reality.